The TON, also known as Timer ON, an instruction is used to keep track of time of occurrence of certain events. The conditions preceding the TON instruction will allow the timer to start counting up to a specified value. Once this value is reached, the program will set specific internal bits notifying the programmer as well as other instructions within the PLC that the timer has finished counting. Furthermore, experienced developers can leverage the instruction to know when a certain process is being executed.

The TON instruction is a composite instruction which means that it will contain a timer, integers as well as booleans. Depending on the application, you may not need to use all of them.

An Allen Bradley timer instruction is common to be seen in RSLogix 5, 500, 5000 as well as Studio 5000. A timer is needed in many PLC applications and is used to delay a certain condition. An example of a required timer would be during a startup sequence. As a process is initiated via a "start" push button, each element is started based on a sequence. If there's a way to get the status of these elements, it's possible to avoid using timers. In other words, once an output is set to start a motor, the user may receive feedback that confirms that the motor is running at speed. If such an input is missing, it's possible to issue a timer delay that would assume that the motor is running after a certain time. Example: Once the motor is started, wait 5 second; start the next step.

Example & Usage of TON

Here’s a real-world scenario of a TON instruction:

  1. A Micrologix 1100 Allen Bradley PLC is used to control a process.
  2. A “Tank Cooling Sequence” is initiated by an internal bit B3:0/4.
  3. The bit above is tied to an XIC instruction which enables the TON instruction.
  4. The TON instruction specifies a Timer in the PLC: T4:0
  5. The Time Base of T4:0 is set to 1.0 which translates to the timer counting in seconds.
  6. The “Preset” of T4:0 is set to 2000 which translates to the timer counting up to 2000 seconds.
  7. The “Accum” of T4:0 is set to 0 which translates to the timer starting to count from 0.
  8. As the timer is initialized by the B3:0/4 XIC, it starts to count.
  9. As the timer counts, the .EN and the .TT bits are set to HIGH.
  10. As the timer finishes counting, the .TT bit is set to LOW and the .DN bit is set to HIGH.
  11. IF the B3:0/4 bit is set to LOW while the timer is counting, the Accum is set back to 0. The .EN, .TT and .DN bits are set to LOW.

Programming example in RSLogix 500:

TON PLC Instruction RSLogix 500

Outcome:

The TON instruction will begin counting as soon as the B3:0/4 XIC is energized. The timer will begin counting at from 0 until it reaches the value specified by the “Preset” integer. In the example above, this value is set to 2000. It’s important to note that the “Time Base” of our timer is set to 1. This translates to a 2000 x 1.0 multiplier for our time. In other words, the timer will count to 2000 seconds.

The timer will set different auxiliary bits during operation. These bits are .EN, .TT and .DN. The .EN bit will be set to HIGH if the timer is energized by the input instructions leading to it. The .TT bit is set to HIGH while the timer is counting; the “Accum” is less than “Preset”. The .DN bit is set to HIGH once the timer reaches the final value. In other words, when the “Accum” is equal to the “Preset”.

Data Types Allowed for TON

The TON leverages a specific data structure, called the Timer, present in most PLC systems.

  • Timer – The high-level instruction specification of all the inner structures.
  • .PRE – Integer specifying up to which value the timer will count.
  • .ACC – Integer specifying the current time value of the timer.
  • .BASE – Selectable value which specifies the time multiplier for the timer.
  • Note1: This is not available in RSLogix 5000; the timers are specified in milliseconds by default.
  • .EN – Boolean value which is set to HIGH when the timer is energized.
  • .TT – Boolean value which is set to HIGH when the timer is in the process of counting.
  • .DN – Boolean value which is set to HIGH when the timer is finished counting.

Important Notes

  • Note 1 – The TON instruction uses a timer which is specified internally to the PLC. The user may choose to set the values covered above through the PLC interface instead of working with them in the instruction. Furthermore, the TON instruction will not display the current set of all the bits discussed above; they will be set on the PLC only.
  • Note 2 – The programmer may choose to leverage any or none of the bits and /or integers described above. For example, a common practice would leverage the LIM instruction to execute something within a window of the timer based on the “Accum” value.

Video Tutorial

Back to tutorials

Got a question or comment?

Related Tutorials

Beginner

Opto 22 groov RIO Getting Started

The groov RIO module from Opto 22 has been released only a few months ago. The groov RIO is a feature packed piece of hardware that is easy to install, configure and deploy for many different field applications. The module comes pre-loaded with an array of software tools used across the industry and is ready to hit the floor running out of the box. Furthermore, the module is equipped with user configurable input and output nodes that have the capability unlike anything else on the market.

August 2, 2020
|
By
Vladimir Romanov
Beginner

Micro800 PLC Programming Getting Started

The Micro800 Control Systems by Rockwell Automation provide a cost effective solution for small to medium automation systems. The controllers within this family are typically used on stand alone machines or small process applications. The family offers five distinct controller types that are further customizable through add-on modules: Micro810, Micro820, Micro830, Micro850 and Micro870.Micro800 Programmable Logic Controllers Getting StartedUnlike the other Rockwell Automation controllers, this line of PLCs is programmed through a dedicated software: Connected Components Workbench. From within this tool, the programmer can flash the firmware, load the program and monitor the state of the controller. Furthermore, Connected Components Workbench (CCW) is often used to program other non-PLC Rockwell Automation devices such as Variable Frequency Drives (VFDs) and certain Safety Relays.

July 26, 2020
|
By
Vladimir Romanov
Beginner

An Introduction to DeviceNet Industrial Networks

In this tutorial you will learn about the DeviceNet industrial network, go over a basic offline configuration, and explore some advanced features.

July 24, 2020
|
By
Jacques Venter